| Units | LX180 |
LX305 |
LX440 |
|||||
| Storage Cylinder | ||||||||
| Capacity | litres | 177 |
294 |
429 |
||||
| Outside Dimensions | mm | 571 x 1215 |
571 x 1905 |
571 x 2700 |
||||
Heating Circuit Capacity |
litres | 5 |
9 |
12 |
||||
| Weight - Full | kg | 237 |
378 |
545 |
||||
| Weight - Empty | kg | 60 |
84 |
116 |
||||
| Working Pressure | kPa | 850 |
850 |
850 |
||||
| Insulation (Polyutherane) Thickness | mm | 47 |
47 |
47 |
||||
| Solar Collectors | ||||||||
| Number of | - | 1 |
2 |
3 |
||||
| Dimensions | mm | 1941 x 1027 |
1941 x 2094 x 84 |
1941 x 3181 x 84 |
||||
| Nominal Surface Area | m2 | 2 |
4 |
6 |
||||
| Weight - Full | kg | Refer to specific collector data sheet |
||||||
| Weight - Empty | kg | Refer to specific collector data sheet |
||||||
| Total System | ||||||||
| Dimensions - area on roof | mm | 2562 x 1615 |
2562 x 2494 |
2562 x 3581 |
||||
| Weight - Full* | kg | 277 |
455 |
659 |
||||
| Weight - Empty* | kg | 98 |
157 |
225 |
||||
| * Total system weight based on use of Australis series collectors | ||||||||
| Water Supply | ||||||||
| TPR Valve Setting | kPa | 850 |
psi |
125 |
||||
| ECV* Setting | kPa | 700 |
psi |
100 |
||||
| Max. supply pressure with ECV | kPa | 550 |
psi |
80 |
||||
| Max. supply pressure without ECV | kPa | 680 |
psi |
100 |
||||
| Min. supply pressure | kPa | 200 |
psi |
29 |
||||
| Electric Boost Specifications | ||||||||
| Heating Unit Type | Copper Sheath Immersion Element |
|||||||
| Supply Voltage | 220 V - 250 V |
|||||||
Hourly recovery rate @ temperature rise of: |
||||||||
| Rating | Current | 40 |
50 degrees C |
60 degrees C |
||||
| kW | Amps | litres / hour |
litres / hour |
litres / hour |
||||
| 2.4 | 10 | 52 |
41 |
34 |
||||
| 3.6 | 15 | 77 |
62 |
52 |
||||
CONTACT US